Carrier gas furnace · exact code

Carrier gas furnace code 33: meaning and exact next steps

33 means The limit, draft safeguard, flame rollout or blocked-vent switch is open, or the furnace is running in high-heat only because of 2 successive low-heat limit trips. The blower runs for 4 minutes or until the switch remakes, whichever is longer. If the switch stays open longer than 3 minutes the code becomes lockout 13. A flame rollout switch needs a manual reset. This answer applies only to Carrier variable-speed, two-stage induced-combustion gas furnaces (the 58CVA and 58CVX covered by Carrier's guide TG-GFC80-02) that flash a two-digit status code on an amber LED. The first digit is the number of short flashes and the second is the number of long flashes. Other Carrier boards use the same idea, but their code list is on their own door label.

On the covered Carrier gas furnace, 33 means the limit, draft safeguard, flame rollout or blocked-vent switch is open, or the furnace is running in high-heat only because of 2 successive low-heat limit trips. The blower runs for 4 minutes or until the switch remakes, whichever is longer. If the switch stays open longer than 3 minutes the code becomes lockout 13. A flame rollout switch needs a manual reset. First, turn the thermostat down, replace a dirty filter, open all supply and return registers, and confirm the blower is running.

Try in this order

0 of 2 completed
  1. What to do first

    Reversible

    Turn the thermostat down, replace a dirty filter, open all supply and return registers, and confirm the blower is running.

  2. Correct only the documented fault domain

    Reversible

    The most common owner-fixable cause is restricted airflow that overheats the limit. If 33 comes back with a clean filter and open registers, the guide sends a technician through the limit switch, the rollout switch, the blocked-vent switch, the draft safeguard, the vent (restriction, sizing, elbow baffle, wind) and the wiring harness. Never bypass these switches.

Evidence ledger

Sources behind this answer

Exact questions

Common questions about “Carrier gas furnace code 33”

What does 33 mean on a Carrier gas furnace?+

The limit, draft safeguard, flame rollout or blocked-vent switch is open, or the furnace is running in high-heat only because of 2 successive low-heat limit trips. The blower runs for 4 minutes or until the switch remakes, whichever is longer. If the switch stays open longer than 3 minutes the code becomes lockout 13. A flame rollout switch needs a manual reset.

Wrong device or version?

Match the path before repeating the steps.

Match another device