Kenmore gas water heater showing LED flashes 3 times every 3 seconds: meaning and exact next steps

LED flashes 3 times every 3 seconds means Kenmore's service table lists this code as: air pressure switch open. This answer applies only to Kenmore gas water heater as covered by the Kenmore code table on Sears PartsDirect for this appliance type. A different Kenmore series, or the code list of the company that built the appliance, may word or number these codes differently.

On the covered Kenmore gas water heater, LED flashes 3 times every 3 seconds means Kenmore's service table lists this code as: air pressure switch open. First, make sure there are no blockages in the blower or venting system. Then: check for proper venting according to the installation instructions. A long vent or blocked vent can prevent the pressure switch from closing when blower is running. NOTE: The blower high-limit switch is wired in series with the air pressure switch. Ensure blower high-limit switch is not open. Check for electrical continuity across high-limit switch and replace switch if contacts remain open. Parts named: air pressure switch, High-limit switch, Gas control.

Differential

Likely causes of “Kenmore gas water heater showing LED flashes 3 times every 3 seconds”, and how to tell them apart

  1. 1

    A blockage in the blower or the venting system

    What separates it The LED flashes 3 times every 3 seconds while the blower runs

    How to confirm Look for a blockage in the blower and along the vent; the chart starts there

  2. 2

    A vent that is too long or blocked for the pressure switch to close

    What separates it The install has a long vent run and the switch never closes when the blower is running

    How to confirm Compare the vent to the installation instructions; a long or blocked vent stops the switch closing

  3. 3

    A blower high-limit switch that is open

    What separates it The high-limit switch is wired in series with the air pressure switch and has tripped

    How to confirm Check for continuity across the blower high-limit switch, with the power off

  4. 4

    An air pressure switch that will not close

    What separates it The vent is clear and the high-limit switch is closed but the fault repeats

    How to confirm Have the contacts checked and replaced if the chart's steps do not clear it

Before you touch a setting

Record this first — changing settings destroys the evidence

  • That the LED flashes 3 times every 3 seconds, the air pressure switch open pattern
  • How long the vent run is and whether anything blocks it
  • Whether the blower high-limit switch shows continuity

Try in this order

0 of 5 completed
  1. What to do first

    Reversible

    Make sure there are no blockages in the blower or venting system.

  2. Correct only the documented fault domain

    Reversible

    Check for proper venting according to the installation instructions. A long vent or blocked vent can prevent the pressure switch from closing when blower is running. NOTE: The blower high-limit switch is wired in series with the air pressure switch. Ensure blower high-limit switch is not open. Check for electrical continuity across high-limit switch and replace switch if contacts remain open. Parts named: air pressure switch, High-limit switch, Gas control.

  3. Make sure there are no blockages in the blower or the venting

    Reversible

    Check for proper venting against the installation instructions, because a long or blocked vent can keep the switch from closing while the blower runs.

  4. Check the blower high-limit switch

    Reversible

    The chart notes the high-limit switch is wired in series with the air pressure switch, so an open high-limit gives the same 3-flash pattern.

  5. Replace the high-limit switch if the contacts stay open

    Reversible

    Test for continuity across the switch with the power off; the chart replaces the high-limit switch if its contacts remain open, and names the air pressure switch and gas control as the other parts.

Model-specific

What is true of this model and not of its siblings

Parts named by the chart
Air pressure switch, high-limit switch and gas control.

Stop boundary

When this stops being a self-service repair

  • !Do not run the heater with a blocked vent while you investigate the 3-flash fault, since the pressure switch is protecting against poor venting

Evidence ledger

Sources behind this answer

Where the manufacturer's article stops. The vent check, the series high-limit note and the continuity test are chart text; the gas leak advice is general safety guidance.

Exact questions

Common questions

What does LED flashes 3 times every 3 seconds mean on a Kenmore gas water heater?+

Kenmore's service table lists this code as: air pressure switch open.

Can a long vent cause it?+

Yes, the chart says a long or blocked vent can prevent the switch closing.

What is wired in series with the switch?+

The blower high-limit switch, so check that it is not open.