Rinnai tankless water heater · exact code

Rinnai tankless water heater code 05: meaning and exact next steps

05 means A fault in the by-pass flow control device. This answer applies only to Rinnai SENSEI-series residential tankless water heaters (for example the RUR-series with-pump models) as documented on Rinnai's N-series tech sheet, document 100000507. Rinnai's older non-SENSEI models share many code numbers but use a different table, so confirm the code against your unit's own data sheet.

On the covered Rinnai tankless water heater, 05 means a fault in the by-pass flow control device. First, turn the water heater's power off and back on once and run a hot tap. Then: Rinnai directs measuring the resistance of the by-pass flow control and replacing the device if it is out of range. If 05 reappears after the reset with hot water running, Rinnai's diagnostic manual says to replace the bypass valve.

Differential

Likely causes of “Rinnai tankless water heater code 05”, and how to tell them apart

  1. 1

    A failed bypass flow control

    What separates it Code 05 returns while hot water runs

    How to confirm Rinnai says to replace the bypass valve

  2. 2

    A wiring or connector fault

    What separates it The measured resistance is wrong

    How to confirm Technician measures the resistance

  3. 3

    Scale in the valve

    What separates it Hard water

    How to confirm Flush and treat the water

  4. 4

    A stuck valve

    What separates it Temperature swings

    How to confirm Technician inspection

Before you touch a setting

Record this first — changing settings destroys the evidence

  • Whether hot water was running
  • Your water hardness

Try in this order

0 of 6 completed
  1. What to do first

    Reversible

    Turn the water heater's power off and back on once and run a hot tap.

  2. Correct only the documented fault domain

    Reversible

    Rinnai directs measuring the resistance of the by-pass flow control and replacing the device if it is out of range. If 05 reappears after the reset with hot water running, Rinnai's diagnostic manual says to replace the bypass valve.

  3. Turn the power off and on once

    Reversible

    Then run a hot tap.

  4. Watch for the code

    Reversible

    With water running.

  5. Check your water hardness

    Reversible

    And any softener.

  6. Note the code history

    Reversible

    For the technician.

Model-specific

What is true of this model and not of its siblings

The bypass valve
A tankless heater can overshoot, so the bypass valve mixes in cold water to hold the set temperature. If it fails, the temperature swings or the control reports code 05.
Rinnai's diagnosis
Rinnai directs measuring the resistance of the bypass flow control and replacing it if the reading is out of range. If 05 returns after a reset with hot water running, its manual says to replace the bypass valve.
Preventing a repeat
Scale makes valves stick. A yearly flush and treating hard water extend the life of the valve.
Why the bypass exists
A tankless heater heats water as it passes and can overshoot when the flow changes suddenly, for example when someone turns down a tap. The bypass flow control mixes in a little cold water so that the outlet temperature stays steady. When the valve cannot move, the heater cannot hold the temperature, and it reports 05.
What you would notice
Hot water that swings between too hot and too cold, particularly at low flow, is the typical sign. Running a tap on hot at a trickle makes the swing obvious. A steady supply at higher flow may seem normal, so the fault can hide until a shower is turned down.
What the technician measures
Rinnai's diagnosis is a resistance measurement of the valve's motor, compared with the range in the service manual. A reading outside the range means replacement; a good reading sends the technician on to the wiring and the board.

Stop boundary

When this stops being a self-service repair

  • !Rinnai says to replace the bypass valve if 05 returns with hot water running
  • !This is a technician repair
  • !Treat hard water to prevent a repeat

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does 05 mean on a Rinnai tankless water heater?+

A fault in the by-pass flow control device.

What does the valve do?+

It mixes some cold water to set the temperature.

Is it a DIY job?+

No.

What causes it?+

A failed valve, wiring or scale.