A gas furnace that will not heat needs six things in order: a thermostat set to Heat and calling above room temperature, power at the furnace switch and breaker, a clean filter with open returns, gas at the shut-off valve, a successful ignition, and a heat cycle that finishes without a safety switch tripping. Trane's troubleshooting guidance starts with the thermostat, then the furnace switch and breaker, then the filter and registers, and treats the gas supply and ignition system as the point to call a technician.
If the furnace has a status light, its flash count or displayed code names the step that failed: Carrier furnaces flash a two-digit code and Lennox furnaces show an E-code, and both lists are on this site. Never bypass a limit, rollout or pressure switch, and if you smell gas, leave the house and call the gas utility from outside.
What this covers
- Residential gas forced-air furnaces with a thermostat, a furnace power switch or breaker, a filter and a status light or display
- A furnace that does not start, starts and stops, or runs without warming the house
- Customer-accessible checks only: thermostat, power, filter, registers, gas shut-off position and the status light
What it does not cover
- ×Oil, electric-resistance and boiler systems
- ×Heat pumps, which have a separate auxiliary-heat page
- ×Opening the furnace, testing gas pressure, cleaning burners or flame sensors, or any live electrical work
Try in this order
0 of 8 completedProve the thermostat is asking for heat
ReversibleTrane's first check is human error: the thermostat must be set to Heat and the temperature in the house must be lower than the setpoint. Some thermostats bring the furnace on automatically while others need a switch or button. Replace batteries in a battery-powered thermostat, look for loose wiring on a hard-wired one, and read any error code shown on a programmable thermostat.
Confirm the furnace has power
ReversibleA gas furnace still uses electricity for the blower, ignition and control board. Look for a switch that resembles a light switch on the side of the furnace, on a nearby wall or on a ceiling joist, and make sure it is on. Check the breaker panel. Trane says to switch a tripped breaker back on once and to call for service if it trips again, because that means an electrical problem. Another Trane guide says not to reset a tripped breaker at all, because it most likely tripped for a problem in the furnace. If in doubt, leave it off and call.
Check the filter and open every return and register
ReversibleChange the filter if it looks dirty or you cannot remember when it was changed. Trane's guidance is every 1 to 3 months depending on the filter, and Carrier lists a clogged filter and closed vents as the first quick fix for weak or uneven heat. Move furniture and curtains off registers and return grilles. Restricted airflow makes the furnace overheat and shut itself off.
Watch what the furnace does, without opening it
ReversibleNote whether the inducer fan starts, whether you hear clicking with no flame, whether the blower runs, and what the status light does. Trane says not to take the front panel off while the furnace is running, and that a blower door switch cuts power and gas when the door is removed. Some furnaces have a light you can see from outside; on others it is on the control board behind the panel, which is a technician's view.
Check the gas shut-off is on
ReversibleTrane says the gas shut-off is usually within a few feet of the furnace, on a black or copper pipe, with a knob or lever, and that it should be in the ON position. When in doubt, contact a professional. A rotten-egg smell means leave the house and call the gas company; do not investigate further.
Older furnace with a standing pilot
ReversibleTrane notes that furnaces built before about 2010 may have a standing pilot light rather than electronic ignition. If the pilot is out, relight it following the lighting instructions on the furnace itself. If it will not stay lit, stop and call for service.
Read the status light and match it to the exact model
ReversibleRecord the color, whether it flashes, how many long and short flashes, and any displayed code. For a Carrier furnace the code is two digits: the first is the number of short flashes and the second the number of long flashes. Match it on this site's Carrier or Lennox code list, or, for any other brand, take a photo or video of two full repetitions for your technician. Write down the furnace brand and model number too.
Know when the checks are finished
ReversibleTrane's rule is simple: if the furnace has power, the thermostat is set to Heat and the filter is clean and it still will not run, call an HVAC company. Lockouts, ignition failures, pressure-switch faults, gas-valve problems and control-board faults are all technician work. Tell the person booking the visit what lights or codes you saw, plus the brand and model.
Evidence ledger
Sources behind this answer
Trane's own guide: thermostat set to Heat and colder than the setpoint, batteries, the furnace switch and breaker, filter and registers, gas supply and igniter, and when to call.
Trane's own guide: thermostat, power, filter, gas shut-off valve, igniter, flame sensor, pilot light on pre-2010 furnaces and dirty burners, with what to leave to a technician.
Carrier's own guide to the signs a furnace needs repair, common causes and quick checks, and the problems that need a professional.
Carrier's own guide for the 58CVA and 58CVX. Two-digit status codes flashed on an amber LED, each with its own section.
Exact questions
Common questions about “Furnace runs or calls for heat but the house stays cold”
Why does my furnace click but not light?+
Clicking with no flame usually means the ignition sequence is running and the burners are not lighting or proving flame. Trane lists a dirty or failed igniter, a dirty flame sensor, the gas supply and dirty burners as causes and says to leave all of these to a technician. Note the status light before you call.
Is it safe to reset the furnace over and over?+
No. A furnace that keeps locking out is telling you something. Repeated resets can hide a safety-switch trip. Change the filter, reset the power once, and if it locks out again, call for service.
What does a blinking light on the furnace mean?+
It depends on the make and model. Trane says a slow green blink can simply mean no call for heat, while red blinking generally signals a problem. Carrier flashes a two-digit code. Match the exact pattern to your model's own legend and never assume a meaning from another brand.
How often should I change the furnace filter?+
Trane says every 1 to 3 months depending on the filter, and some Trane pages say every 30 to 90 days. A clogged filter is one of the most common causes of overheating shutdowns.
When is no heat an emergency?+
Immediately if you smell gas, a carbon-monoxide alarm sounds, or you see soot, scorching or a disconnected vent pipe. Leave the house and call from outside. In cold weather, also treat a fully dead furnace with children, elderly people or frozen pipes at risk as urgent.
Why does the furnace run but the house stays cold?+
Causes include a dirty filter, blocked ducts, a failed blower or a thermostat problem.
What should I check first?+
Replace the filter, check the thermostat is in heat mode and confirm vents are open.
When do I call for service?+
If warm air is not reaching rooms after those checks, a technician should look.