Carrier gas furnace code 23: meaning and exact next steps

23 means The low-heat or high-heat pressure switch was already made (closed) when the thermostat called for heat. The control flashes 23 until the switch opens, then starts the cycle. This answer applies only to Carrier variable-speed, two-stage induced-combustion gas furnaces (the 58CVA and 58CVX covered by Carrier's guide TG-GFC80-02) that flash a two-digit status code on an amber LED. The first digit is the number of short flashes and the second is the number of long flashes. Other Carrier boards use the same idea, but their code list is on their own door label.

On the covered Carrier gas furnace, 23 means the low-heat or high-heat pressure switch was already made (closed) when the thermostat called for heat. The control flashes 23 until the switch opens, then starts the cycle. First, turn off the thermostat call, wait a minute, and start one normal heating cycle to see whether the code repeats.

Differential

Likely causes of “Carrier gas furnace code 23”, and how to tell them apart

  1. 1

    A pressure switch stuck closed

    What separates it Code 23 shows before the furnace starts

    How to confirm Carrier's flowchart ends at replacing the switch or the control

  2. 2

    A short in the switch wiring

    What separates it The circuit reads closed all the time

    How to confirm Technician inspection

  3. 3

    Condensate in the tubing

    What separates it The switch reads wrongly

    How to confirm Technician draining

  4. 4

    A control fault

    What separates it The switch tests well

    How to confirm Technician replacement

  5. 5

    A temporary glitch

    What separates it The code clears and does not return

    How to confirm Run one normal cycle

Before you touch a setting

Record this first — changing settings destroys the evidence

  • That the code reads 23
  • Whether it clears once the call ends
  • Recent service
  • The model number

Try in this order

0 of 8 completed
  1. What to do first

    Reversible

    Turn off the thermostat call, wait a minute, and start one normal heating cycle to see whether the code repeats.

  2. Correct only the documented fault domain

    Reversible

    A pressure switch that is already closed before the inducer runs points to a stuck switch or a short in its wiring. Carrier's flowchart ends at replacing the low-heat or high-heat pressure switch or its assembly, or the furnace control. Never jumper a pressure switch: it is what proves the vent is drawing.

  3. Turn off the thermostat call

    Reversible

    Wait a minute.

  4. Start one normal cycle

    Reversible

    Watch the display.

  5. Note whether 23 repeats

    Reversible

    And when.

  6. Do not touch the switch

    Reversible

    Or its tubes.

  7. Record the date

    Reversible

    And weather.

  8. Call a technician

    Reversible

    If it repeats.

Model-specific

What is true of this model and not of its siblings

A check before every start
The control wants the pressure switches open at rest. If one is closed, it flashes 23 until it opens and only then starts.
What Carrier says
Carrier's flowchart ends at replacing the low-heat or high-heat pressure switch or assembly, or the control.
Never jumper
A pressure switch proves that the vent is drawing.
Condensate
Water in the tube can hold a diaphragm.
A single occurrence
If the code appears once and clears, note it and watch.
Technician tests
A meter, a manometer and a visual inspection.
The switch must open first
At the start of a call for heat, the pressure switches should be open because no air is moving. A switch that is closed at that moment is either stuck, shorted or reading a pressure that should not be there. The control flashes 23 and waits for it to open.
Do not jumper
It can be tempting to short the switch's terminals to get the furnace running. A pressure switch confirms that the vent is drawing exhaust out of the house. Defeating it risks carbon monoxide in the home, and Carrier says never to do it.
What the repair is
Carrier's flowchart ends at replacing the pressure switch or its assembly, or the furnace control. The technician decides which with a meter and a manometer. Ask whether the new switch matches the model's part number.

Stop boundary

When this stops being a self-service repair

  • !Never bypass, jumper or tape over a safety switch
  • !Stop for a carbon monoxide alarm, soot, scorch marks or flame outside the burner compartment
  • !Call a qualified technician for anything behind the furnace's panels
  • !If you smell gas, leave the building and call the gas utility from outside; do not use switches or phones inside

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does 23 mean on a Carrier gas furnace?+

The low-heat or high-heat pressure switch was already made (closed) when the thermostat called for heat. The control flashes 23 until the switch opens, then starts the cycle.

Will it clear by itself?+

The control waits for the switch to open.

Wrong device or version?

Match the path before repeating the steps.

Match another device