Kenmore 417 series laundry center dryer · exact showing

Kenmore 417 series laundry center dryer showing E65 -- 6 beeps, 5 beeps: meaning and exact next steps

E65 -- 6 beeps, 5 beeps means Kenmore's service table lists this code as: too many high-limit thermostat trips. This answer applies only to Kenmore 417 series laundry center dryer as covered by the Kenmore code table on Sears PartsDirect for this appliance type. A different Kenmore series, or the code list of the company that built the appliance, may word or number these codes differently.

On the covered Kenmore 417 series laundry center dryer, E65 -- 6 beeps, 5 beeps means Kenmore's service table lists this code as: too many high-limit thermostat trips. First, clean the lint screen and the exhaust vent duct system to the outside of your home.

Differential

Likely causes of “Kenmore 417 series laundry center dryer showing E65 -- 6 beeps, 5 beeps”, and how to tell them apart

  1. 1

    The high-limit thermostat has tripped too many times

    What separates it The dryer shuts off hot and the code shows

    How to confirm Clean the lint screen and look at the exhaust duct

  2. 2

    A clogged lint screen or exhaust vent

    What separates it The dryer takes a long time to dry and the cabinet gets hot

    How to confirm Clear the screen, the housing and the duct to the outside

  3. 3

    A thermistor reading out of range

    What separates it The temperature sensor measures over 60,000 ohms at room temperature

    How to confirm Measure the thermistor with the dryer unplugged

  4. 4

    A heater relay stuck closed on the control board

    What separates it The heater stays on and the dryer overheats

    How to confirm Measure the relay prongs for infinite resistance

  5. 5

    A kinked or crushed exhaust duct

    What separates it The dryer was moved or pushed against the wall

    How to confirm Pull the dryer out and check the duct

Before you touch a setting

Record this first — changing settings destroys the evidence

  • That the code is E65 and the beep pattern
  • How long the dryer takes to dry a load
  • Whether the lint screen and duct are clean

Try in this order

0 of 11 completed
  1. What to do first

    Reversible

    Clean the lint screen and the exhaust vent duct system to the outside of your home.

  2. Correct only the documented fault domain

    Reversible

    A clogged screen or exhaust vent duct can cause the dryer to overheat. If the exhaust system is clear, unplug the laundry center and check the resistance of the thermistor (temperature sensor). You should measure around 50,000 ohms at room temperature (77 degrees F). Replace the thermistor if you measure over 60,000 ohms. Unplug the wires from the heater relay on the dryer electronic control board. Measure the resistance through the prongs on the heater relay. You should measure infinite resistance. If you measure near 0 ohms of resistance, replace the dryer electronic control board because the heater relay is stuck closed. Parts named: thermistor, dryer electronic control board.

  3. Clean the lint screen and the exhaust vent duct system to the outside of your home

    Reversible

    A clogged screen or duct can cause the dryer to overheat, which trips the high-limit thermostat repeatedly.

  4. If the exhaust system is clear, unplug the laundry center and check the thermistor

    Reversible

    You should measure around 50,000 ohms at room temperature (77 degrees F). Replace the thermistor if you measure over 60,000 ohms.

  5. Check the heater relay on the dryer electronic control board

    Reversible

    Unplug the relay wires and measure across the prongs. You should measure infinite resistance; near 0 ohms means the relay is stuck closed, so replace the board.

  6. Clean the lint screen

    Reversible

    Pull the screen out, remove the lint and wash it if it has a film from fabric softener, then look inside the housing.

  7. Clean the exhaust duct

    Reversible

    Disconnect the duct at the back and clear it to the outside of the home. A clogged screen or vent causes the overheating that trips the thermostat.

  8. Unplug the laundry center

    Reversible

    Before you measure anything, unplug it so that no live voltage is present.

  9. Measure the thermistor

    Reversible

    The thermistor should read around 50,000 ohms at about 77 degrees Fahrenheit, and it is replaced if it reads over 60,000 ohms.

  10. Check the heater relay

    Reversible

    Unplug the wires from the heater relay on the dryer board and measure the prongs, which should read infinite resistance. Near zero ohms means the relay is stuck closed.

  11. Replace the part that fails

    Reversible

    Replace the thermistor if it is out of range, or the dryer electronic control board if the relay is stuck closed.

Model-specific

What is true of this model and not of its siblings

The code on this page
E65, shown with six beeps and five, for too many high-limit thermostat trips.
Parts involved
The lint screen, the exhaust duct, the thermistor and the dryer control board.
Source
Sears PartsDirect's table for Kenmore 417 laundry centers.

Stop boundary

When this stops being a self-service repair

  • !Stop using the dryer until the exhaust is cleared, because an overheating dryer is a fire risk
  • !Unplug the laundry center before you measure anything
  • !If the exhaust is clear and E65 returns, a technician should check the thermistor and the heater relay
  • !Unplug the laundry center before checking any part
  • !Never run a dryer with a blocked vent, since it is a fire risk

Evidence ledger

Sources behind this answer

Where the manufacturer's article stops. The clean-first order, the 60,000 ohm limit and the relay test are chart text.

Exact questions

Common questions

What does E65 -- 6 beeps, 5 beeps mean on a Kenmore 417 series laundry center dryer?+

Kenmore's service table lists this code as: too many high-limit thermostat trips.

What does E65 mean on a Kenmore 417 laundry center dryer?+

The high-limit thermostat has tripped too many times, which means the dryer has been overheating.

Is the vent usually the cause?+

Yes, a clogged lint screen or exhaust duct is the usual cause.

What should the thermistor read?+

Around 50,000 ohms at room temperature, and it is replaced above 60,000 ohms.

Is a stuck relay possible?+

Yes, a heater relay stuck closed on the control board keeps the heater on.

Is it dangerous to ignore?+

A dryer that overheats is a fire risk, so fix the cause before running it.