Lennox gas furnace code E272: meaning and exact next steps

E272 means Soft lockout: the maximum number of recycles was exceeded and the last recycle was due to the pressure switch opening. It clears when a heat call finishes successfully. This answer applies only to Lennox gas furnaces that use the 103130-XX integrated ignition control, as documented in the Lennox service literature for the Elite EL296UHV(X). Codes appear as E followed by three digits on the control or on the thermostat. Other Lennox controls have their own tables.

On the covered Lennox gas furnace, E272 means soft lockout: the maximum number of recycles was exceeded and the last recycle was due to the pressure switch opening. It clears when a heat call finishes successfully. First, check the outdoor intake and exhaust terminations for snow, ice or debris.

Differential

Likely causes of “Lennox gas furnace code E272”, and how to tell them apart

  1. 1

    The maximum recycles exceeded because the pressure switch opened

    What separates it E272 appears and the furnace stops

    How to confirm Lennox words it as a soft lockout

  2. 2

    A blocked intake or exhaust

    What separates it Snow, ice or debris outside

    How to confirm Check the terminations

  3. 3

    A low-pressure switch stuck closed

    What separates it The switch does not follow

    How to confirm Technician testing

  4. 4

    A weak combustion air inducer

    What separates it The inducer is slow

    How to confirm Technician testing

  5. 5

    A high-pressure switch that does not close

    What separates it The switch closes late

    How to confirm Technician measurement

Before you touch a setting

Record this first — changing settings destroys the evidence

  • That the code reads E272
  • Whether it clears after a heat call
  • Whether the terminations are clear
  • The weather

Try in this order

0 of 8 completed
  1. What to do first

    Reversible

    Check the outdoor intake and exhaust terminations for snow, ice or debris.

  2. Correct only the documented fault domain

    Reversible

    Lennox says to check whether the low-pressure switch is stuck closed on a heat call, check the pressure at which the high-pressure switch closes, measure operating pressure, and inspect the vent and combustion air inducer.

  3. Look outside

    Reversible

    At intake and exhaust.

  4. Clear snow or debris

    Reversible

    Carefully.

  5. Let it restart

    Reversible

    A soft lockout clears after a good call.

  6. Watch one cycle

    Reversible

    Time it.

  7. Note whether it repeats

    Reversible

    And when.

  8. Call a technician

    Reversible

    For pressure tests.

Model-specific

What is true of this model and not of its siblings

A soft lockout
The control stops after too many recycles but can try again.
Lennox's checks
Whether the low-pressure switch is stuck closed on a heat call, the pressure at which the high-pressure switch closes, the operating pressure, the vent and the combustion air inducer.
Outside
A blocked termination is the first look.
Inducer
A slow inducer lets pressure drop.
Records
Note when it appears.
Safety
Never bypass.
Soft and hard lockouts
A soft lockout stops the furnace but lets the control try again, often after a delay or when a call completes. A hard lockout needs a reset. Lennox words E272 as soft, so the furnace may recover without help, then trip again.
Reading Lennox's checks
Lennox points a technician to the low-pressure switch, which should not be stuck closed, the pressure at which the high-pressure switch closes, the operating pressure, and the vent and combustion air inducer. They are all about airflow.
Outside work for you
Keep the intake and exhaust clear of snow, ice and leaves, and trim shrubs back from the terminations. If the unit has a condensate line, check that it is not frozen or blocked.
Telling Lennox's causes apart
A switch that is stuck closed on a heat call is a switch fault. A high-pressure switch that closes at the wrong pressure suggests the inducer or the vent. Operating pressure that is low points to an airflow restriction. The technician measures all three, usually with a manometer and a meter.
What clears the lockout
A soft lockout clears itself once a heat call finishes successfully, so the furnace may heat normally for days between events. Keep a note of the dates, because a code that returns during cold or windy weather suggests a vent or termination issue.

Stop boundary

When this stops being a self-service repair

  • !Never bypass, jumper or tape over a safety switch
  • !Stop for a carbon monoxide alarm, soot, scorch marks or flame outside the burner compartment
  • !Call a qualified technician for anything behind the furnace's panels
  • !If you smell gas, leave the building and call the gas utility from outside; do not use switches or phones inside

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does E272 mean on a Lennox gas furnace?+

Soft lockout: the maximum number of recycles was exceeded and the last recycle was due to the pressure switch opening. It clears when a heat call finishes successfully.

Does it clear?+

When a heat call finishes successfully.

What can I check?+

The outside terminations.

Who tests pressures?+

A technician.