On the covered Navien tankless water heater, E740 means abnormal outdoor temperature sensor. Sub-code 1 is open and sub-code 2 is short. It appears only when the outdoor reset curve is enabled. First, look for a loose or damaged outdoor sensor wire.
Differential
Likely causes of “Navien tankless water heater code E740”, and how to tell them apart
- 1
A loose or damaged outdoor sensor wire
What separates it The sensor reads open or short
How to confirm Check the wiring connection
- 2
An outdoor reset curve configured wrongly
What separates it The code appears only with the curve enabled
How to confirm Check the configuration
- 3
A failed outdoor sensor
What separates it Open or short readings
How to confirm Replace the sensor
- 4
Moisture in the sensor connection
What separates it Intermittent readings
How to confirm Dry and seal the connection
Before you touch a setting
Record this first — changing settings destroys the evidence
- Whether the outdoor reset curve is enabled
- The sub-code, one for open or two for short
- The wiring condition
Try in this order
0 of 5 completedWhat to do first
ReversibleLook for a loose or damaged outdoor sensor wire.
Correct only the documented fault domain
ReversibleNavien's actions: ensure the outdoor reset curve is configured properly, and check the outdoor temperature sensor wiring connection.
Check the outdoor sensor wiring
ReversibleFor loose or damaged wire.
Check the reset curve setting
ReversibleIs it enabled?
Note the sub-code
ReversibleOpen or short.
Model-specific
What is true of this model and not of its siblings
- Outdoor reset
- An outdoor reset curve lets a heating system lower its water temperature as the weather warms, which saves energy. It needs an outdoor sensor, and the code appears when that sensor reads open or short.
- Navien's actions
- Ensure the curve is configured properly and check the sensor wiring connection.
- Weather
- Outdoor wiring suffers from moisture and sun, so a seasonal fault is common.
- Why an outdoor sensor
- Outdoor reset adjusts the supply water temperature to the weather: colder outside, hotter water for the heating loop, and the reverse. The sensor outside tells the heater which way to go. If its wire is cut, shorted or wet, the heater cannot follow the curve.
- Open or short
- Sub-code one means the circuit reads open, as with a broken wire. Sub-code two means it reads short, as with water in the connection. Either points to the sensor and its cable, which are exposed to weather.
- When you do not need it
- If you do not use outdoor reset, the setting can be turned off by a technician, and the code will not appear.
- Checking the sensor outside
- Look at the outdoor sensor and its cable for chewed or cracked insulation, corrosion at the terminals and water inside any splice. A small dab of dielectric grease and a weatherproof connector often cures an intermittent reading.
- Setting up the curve
- If you use outdoor reset, a technician sets the curve so that the supply temperature follows the weather in a way that suits your radiators or floor. A badly set curve wastes energy even when the sensor works, so ask for it to be checked at the same visit.
Stop boundary
When this stops being a self-service repair
- !Navien's actions are the curve setup and the sensor wiring
- !The code appears only when the curve is enabled
Evidence ledger
Sources behind this answer
Exact questions
Common questions
What does E740 mean on a Navien tankless water heater?+
Abnormal outdoor temperature sensor. Sub-code 1 is open and sub-code 2 is short. It appears only when the outdoor reset curve is enabled.
What does E740 mean on a Navien?+
An abnormal outdoor temperature sensor.
What do the sub-codes mean?+
One is open, two is short.
When does it appear?+
Only when the outdoor reset curve is enabled.
Can I turn the curve off?+
A technician can set it up properly.