On the covered Navien tankless water heater, E785 means abnormal flow switch operation. First, check that the cold water line to the heater is fully open. Then: Navien's checks: the cold water line and the flow switch connection. Clean the inlet water filter.
Differential
Likely causes of “Navien tankless water heater code E785”, and how to tell them apart
- 1
The cold water line is not fully open
What separates it The flow switch does not register
How to confirm Open the valve fully
- 2
A flow switch connection fault
What separates it The reading drops out
How to confirm Technician checks the connection
- 3
A blocked inlet filter
What separates it Flow is low
How to confirm Clean the inlet water filter
- 4
Low water pressure
What separates it The flow is too weak
How to confirm Check the supply
- 5
A faulty flow switch
What separates it The switch fails
How to confirm Replace it
Before you touch a setting
Record this first — changing settings destroys the evidence
- Whether the cold water valve is open
- Whether flow is weak at the taps
- The inlet filter state
Try in this order
0 of 6 completedWhat to do first
ReversibleCheck that the cold water line to the heater is fully open.
Correct only the documented fault domain
ReversibleNavien's checks: the cold water line and the flow switch connection.
Check the cold water valve
ReversibleFully open.
Clean the inlet filter
ReversibleIf you can reach it safely.
Check water pressure
ReversibleAt other taps.
Call a technician
ReversibleFor the flow switch.
Model-specific
What is true of this model and not of its siblings
- The flow switch
- A tankless heater lights only when water flows, and the flow switch tells it so. If the switch reads wrongly, the heater cannot decide when to fire.
- Navien's checks
- Navien lists the cold water line and the flow switch connection.
- Simple checks
- A half-closed isolation valve, a clogged inlet filter or low supply pressure all reduce flow enough to confuse the switch.
- What the switch tells the heater
- The flow switch closes when enough water passes through the heater. Only then will the burner light. If the switch does not close, or closes erratically, the heater sees no demand and shows E785.
- Simple restrictions
- A cold water isolation valve that is only partly open, a blocked inlet filter or a pinched supply line all reduce the flow below the switch's threshold. Check that every tap on the line runs at normal pressure.
- Low-flow taps
- Some very low-flow fixtures draw less than the minimum flow the heater needs. If E785 appears only at one tap, the fixture may be the cause; try a higher flow at that tap.
- Pressure at other taps
- Run a cold tap and a hot tap elsewhere in the house. If the pressure is weak at all of them, the cause is the supply, not the heater. If it is normal elsewhere, the restriction lies in the heater's own inlet.
- Winter and the supply
- In cold weather, a partly frozen supply pipe or a seasonal drop in pressure can lower the flow. If E785 appears only in the coldest spells, check exposed pipes and insulation, and keep the heater's room above freezing.
- Reading the flow
- Compare the flow at the heater with the flow at the tap by timing how long a bucket takes to fill. Many heaters need a minimum flow, often below a gallon a minute, before the burner lights, and the manual lists it. A flow below that explains the code, and increasing it by opening the tap further is the fix.
Stop boundary
When this stops being a self-service repair
- !Navien's checks are the cold water line and the flow switch connection
- !Call a qualified technician
Evidence ledger
Sources behind this answer
Exact questions
Common questions
What does E785 mean on a Navien tankless water heater?+
Abnormal flow switch operation.
What is the first check?+
The cold water line.
What does the flow switch do?+
It tells the heater water is flowing.