Noritz tankless water heater · exact code

Noritz tankless water heater code 14, EC14: meaning and exact next steps

14, EC14 means A significant overheat of the heat exchanger tripped the thermal fuse and shut the unit down. Noritz says the thermal fuse is a one-time part that is physically broken once it trips. This answer applies only to Noritz tankless water heaters. Several codes apply only to particular series, such as condensing models or the NRCP and CB models, and each page says which. Confirm your model against Noritz's own article.

On the covered Noritz tankless water heater, 14, EC14 means a significant overheat of the heat exchanger tripped the thermal fuse and shut the unit down. Noritz says the thermal fuse is a one-time part that is physically broken once it trips. First, do not attempt to reset or bypass it.

Try in this order

0 of 2 completed
  1. What to do first

    Reversible

    Do not attempt to reset or bypass it.

  2. Correct only the documented fault domain

    Reversible

    Noritz warns never to bypass the thermal fuse. An EC14 cannot be reset: the fuse must be replaced, which means removing the heat exchanger and takes 2 to 4 hours, and Noritz says it is highly recommended to replace the heat exchanger at the same time, because the same scale will cause the code again. The most common cause is scale in the heat exchanger from hard water and no treatment or descaling. Noritz advises a water softener or Scale Shield in hard-water areas.

Evidence ledger

Sources behind this answer

Exact questions

Common questions about “Noritz tankless water heater code 14, EC14”

What does 14, EC14 mean on a Noritz tankless water heater?+

A significant overheat of the heat exchanger tripped the thermal fuse and shut the unit down. Noritz says the thermal fuse is a one-time part that is physically broken once it trips.

Wrong device or version?

Match the path before repeating the steps.

Match another device