Noritz tankless water heater code 20, EC20: meaning and exact next steps

20, EC20 means The high limit switch has been triggered. It trips if water in or leaving the heat exchanger approaches 176 to 205 degrees Fahrenheit. Combustion stops immediately and the unit closes the water control servo. This answer applies only to Noritz tankless water heaters. Several codes apply only to particular series, such as condensing models or the NRCP and CB models, and each page says which. Confirm your model against Noritz's own article.

On the covered Noritz tankless water heater, 20, EC20 means the high limit switch has been triggered. It trips if water in or leaving the heat exchanger approaches 176 to 205 degrees Fahrenheit. Combustion stops immediately and the unit closes the water control servo. First, unplug the unit, let it cool, then plug it back in once.

Try in this order

0 of 2 completed
  1. What to do first

    Reversible

    Unplug the unit, let it cool, then plug it back in once.

  2. Correct only the documented fault domain

    Reversible

    Noritz says this usually requires a hard reset by disconnecting power, and that the most common cause is scale in the heat exchanger. If you keep resetting without fixing the cause you are likely to reach EC14, which is not resettable. If the switch or its wiring is bad, the code usually will not reset even when the unit is cold. Noritz recommends a descale flush, plus a combustion cleaning if there is dust or lint.

Evidence ledger

Sources behind this answer

Exact questions

Common questions about “Noritz tankless water heater code 20, EC20”

What does 20, EC20 mean on a Noritz tankless water heater?+

The high limit switch has been triggered. It trips if water in or leaving the heat exchanger approaches 176 to 205 degrees Fahrenheit. Combustion stops immediately and the unit closes the water control servo.

Wrong device or version?

Match the path before repeating the steps.