York YP9C modulating gas furnace · exact showing

York YP9C modulating gas furnace showing 5 red flashes: meaning and exact next steps

5 red flashes means Rollout switch or condensate pressure switch open. This answer applies only to York YP9C modulating ECM gas furnaces (up to 98% AFUE), whose control board LED flashes red, green or amber, as listed in York's installation manual 5750151-UIM-G-0423. The same manual is issued for the CP9C, LP9C and TP9C models. The LED flashes for a quarter second on and a quarter second off, repeated the number of times of the code, with a two-second pause between sets. Other York furnace families use other pages.

On the covered York YP9C modulating gas furnace, 5 red flashes means rollout switch or condensate pressure switch open. First, note whether the furnace is running and whether condensate is backing up. Then: york's manual says to check the rollout switches on the burner assembly. A rollout switch is a manual-reset switch, reset by pushing the small button in the center of it. If it cannot be reset or if it trips again, York says to contact a qualified serviceman. A tripped rollout switch means flame went where it should not, so do not keep resetting it.

Differential

Likely causes of “York YP9C modulating gas furnace showing 5 red flashes”, and how to tell them apart

  1. 1

    A tripped flame rollout switch

    What separates it The furnace shuts off and the LED flashes five times

    How to confirm Look at the rollout switch on the burner assembly; it has a small red reset button

  2. 2

    A backed-up condensate drain

    What separates it Water in or near the furnace and a full trap

    How to confirm Check that the drain line is not kinked or blocked

  3. 3

    A blocked flue or heat exchanger problem that sent flame the wrong way

    What separates it The rollout switch trips again after a reset

    How to confirm Technician inspection

  4. 4

    A failed switch

    What separates it The switch is open with no cause found

    How to confirm Technician testing

  5. 5

    A one-off trip

    What separates it The furnace restarts after one reset and keeps running

    How to confirm Watch the next few cycles

Before you touch a setting

Record this first — changing settings destroys the evidence

  • That the LED shows five red flashes
  • Whether water is near the furnace
  • Whether the rollout switch can be reset
  • Whether the furnace has tripped before

Try in this order

0 of 8 completed
  1. What to do first

    Reversible

    Note whether the furnace is running and whether condensate is backing up.

  2. Correct only the documented fault domain

    Reversible

    York's manual says to check the rollout switches on the burner assembly. A rollout switch is a manual-reset switch, reset by pushing the small button in the center of it. If it cannot be reset or if it trips again, York says to contact a qualified serviceman. A tripped rollout switch means flame went where it should not, so do not keep resetting it.

  3. Turn the furnace off

    Reversible

    At the switch or breaker.

  4. Look for water

    Reversible

    Around the furnace and the drain.

  5. Check the condensate line

    Reversible

    For a kink or a block.

  6. Press the rollout reset

    Reversible

    Once, if York's manual allows.

  7. Restart and watch

    Reversible

    One full cycle.

  8. Call a technician

    Reversible

    If it trips again.

Model-specific

What is true of this model and not of its siblings

Two switches in one code
York names two possible causes for five flashes, a rollout switch and a condensate pressure switch. They are different problems: one is about flame, the other about water, so look for evidence of each before you decide which you are dealing with.
What the rollout switch protects
If burner flames roll out of the burner compartment, for example because the heat exchanger is blocked, the rollout switch opens and stops the gas. Resetting it removes the protection while the cause is still there, so York says to call a servicer if it trips again.
The condensate side
A high efficiency furnace makes acidic water that drains through a trap and a line. A kinked line, a clogged trap or a frozen outdoor discharge fills the trap and opens the condensate switch.
What you can safely do
Check for water, straighten a visibly kinked hose and press the rollout reset once. Do not remove panels, and do not pour chemicals into the trap.
Records
Note the date, the weather and whether water was present. A frozen discharge in cold weather is a different repair from a failed switch.
After service
Ask the technician to say which switch tripped and why, so that a repeat is easier to diagnose.
Telling water from flame
Look first at the floor around the furnace and at the drain line. Water on the floor, a gurgling trap or a drain line that is full points to the condensate side. A scorched look at the burner compartment, a smell of hot metal or soot around the burner door points to the rollout side. If you see soot or scorch marks, leave the furnace off and call at once, since York treats a repeated rollout trip as a sign of a possible heat exchanger or venting problem.
What a technician will do
They check the rollout switch with a meter, look at the burners and the heat exchanger, run the furnace and watch the flame, and check the condensate trap and drain for blockage. A trap can be cleaned and refilled, and a drain line can be flushed. They also look at the vent pipe slope, which should drain toward the furnace.
Before the first cold snap
Have the furnace serviced each autumn. A yearly visit catches a dirty burner, a clogged trap and a tired inducer before they stop the furnace in the cold, and the visit costs far less than an emergency call at night.

Stop boundary

When this stops being a self-service repair

  • !Never bypass, jumper or tape over a safety switch
  • !Stop for a carbon monoxide alarm, soot, scorch marks or flame outside the burner compartment
  • !Call a qualified technician for anything behind the furnace's panels
  • !If you smell gas, leave the building and call the gas utility from outside; do not use switches or phones inside

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does 5 red flashes mean on a York YP9C modulating gas furnace?+

Rollout switch or condensate pressure switch open.

Can I keep resetting it?+

No, a tripped rollout switch means flame went where it should not.

Is water a clue?+

Yes, a backed-up trap can open the condensate switch.

Wrong device or version?

Match the path before repeating the steps.

Match another device