Goodman gas furnace · exact code

Goodman gas furnace code EEL: meaning and exact next steps

EEL means A problem with the igniter circuit. Goodman lists an improperly connected or shorted igniter, a poor unit ground and an igniter relay fault on the integrated control module. This answer applies only to Goodman GM9C96/GC9C96 and Amana AM9C96/AC9C96 two-stage furnaces with a nine-speed ECM motor, as documented in Goodman's service and troubleshooting manual RS6612020R1. The furnace shows its fault on a seven-segment display, and the codes here are written as that manual prints them. Other Goodman, Amana or Daikin boards can use a different list.

On the covered Goodman gas furnace, EEL means a problem with the igniter circuit. Goodman lists an improperly connected or shorted igniter, a poor unit ground and an igniter relay fault on the integrated control module. First, note whether the furnace clicks or hums with no glowing igniter.

Differential

Likely causes of “Goodman gas furnace code EEL”, and how to tell them apart

  1. 1

    A loose or shorted igniter connection

    What separates it The furnace clicks and the inducer runs but no glow appears

    How to confirm With power off, check that the plug is seated and the leads are undamaged

  2. 2

    A poor furnace ground

    What separates it Intermittent faults that change from call to call

    How to confirm A technician checks the ground wire and the chassis connection

  3. 3

    A failed igniter relay on the control

    What separates it The igniter shows no power at the plug during the ignition step

    How to confirm A technician measures output at the igniter plug during the sequence

Before you touch a setting

Record this first — changing settings destroys the evidence

  • Whether the igniter ever glows orange
  • Any clicking or humming when the call for heat starts
  • Whether the furnace was recently serviced
  • The model and serial number

Try in this order

0 of 5 completed
  1. What to do first

    Reversible

    Note whether the furnace clicks or hums with no glowing igniter.

  2. Correct only the documented fault domain

    Reversible

    Goodman's corrective actions: check and correct the wiring from the integrated control module to the igniter, diagnose and replace a shorted igniter as needed, verify and correct the unit ground wiring, and check the igniter output from the control and replace it if necessary.

  3. Note the sequence at the next call for heat

    Reversible

    Write down whether the inducer starts, whether you hear clicking, and whether a glow appears.

  4. Power the furnace off before inspecting anything

    Reversible

    Turn the furnace power switch off. Look at the igniter plug for melted pins or loose leads.

  5. Correct the wiring, ground or igniter

    Reversible

    Goodman's corrective actions: fix the wiring from the control to the igniter, replace a shorted igniter, correct the ground, and check the igniter output from the control.

Model-specific

What is true of this model and not of its siblings

Shown as
EEL on the control's display.
Applies to
Goodman two-stage furnaces with the integrated control module.

Stop boundary

When this stops being a self-service repair

  • !Do not touch a hot-surface igniter with bare fingers; skin oil can shorten its life
  • !Call for service; igniter and relay checks need a meter and the furnace live

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does EEL mean on a Goodman gas furnace?+

A problem with the igniter circuit. Goodman lists an improperly connected or shorted igniter, a poor unit ground and an igniter relay fault on the integrated control module.

Is replacing the igniter enough?+

Only if the igniter is the fault. The ground and the control output are checked before a new part goes in.

Will it reset itself?+

A restart may clear it briefly, but a real wiring or igniter fault returns on the next call for heat.