On the covered Rheem PowerVent water heater, display 13 and six-three flashes means recycle limit: flame lost. First, check that gas is on to the water heater. Then: Rheem's bulletin lists this as a recycle limit condition where the flame was lost. Flame and gas control work belongs to a technician.
Try in this order
0 of 4 completedWhat to do first
ReversibleCheck that gas is on to the water heater.
Correct only the documented fault domain
ReversibleRheem's bulletin lists this as a recycle limit condition where the flame was lost. Flame and gas control work belongs to a technician.
Check the pilot path
ReversibleSix flashes then three means the flame was lost and the heater hit its recycle limit. Causes include a restricted pilot tube, low gas pressure, carbon on the spark electrode and a blocked combustion air port. Clean the electrode and pilot hood and check the tube for obstruction.
Check the venting
ReversibleA vent run that is long, 30 feet or more, can be too restrictive for the fan to clear the exhaust.
Evidence ledger
Sources behind this answer
Exact questions
Common questions about “Rheem PowerVent water heater display 13 and six-three flashes”
What does display 13 and six-three flashes mean on a Rheem PowerVent water heater?+
Recycle limit: flame lost.