Rheem PowerVent water heater · exact signal

Rheem PowerVent water heater display 44 and two flashes: meaning and exact next steps

display 44 and two flashes means Pressure switch failed closed. This answer applies only to Rheem PowerVent ESII gas water heaters with the Honeywell electronic control, per Rheem Technical Service Bulletin 1627. The gas valve status light flashes a count with a three-second pause, and the electronic control also shows a two-digit display code. Other Rheem water heaters use other controls.

On the covered Rheem PowerVent water heater, display 44 and two flashes means pressure switch failed closed. First, note the code and that the heater will not run normally. Then: Rheem's bulletin lists a pressure switch fault delay of 2 minutes for a switch that has failed open or closed. Pressure switch work belongs to a technician.

Differential

Likely causes of “Rheem PowerVent water heater display 44 and two flashes”, and how to tell them apart

  1. 1

    The pressure switch has failed in the closed position

    What separates it The status light flashes two times and the heater will not run normally

    How to confirm Note the code and that the heater will not run normally

  2. 2

    A switch that is stuck closed

    What separates it The switch contacts have welded

    How to confirm A technician replaces the switch

  3. 3

    A blocked tube to the switch

    What separates it Water or debris has blocked the tube

    How to confirm A technician clears the tube

  4. 4

    A venting problem that confuses the switch

    What separates it The vent or the blower is partly blocked

    How to confirm A technician checks the venting

  5. 5

    A control board fault

    What separates it The switch tests well

    How to confirm A technician checks the control

Before you touch a setting

Record this first — changing settings destroys the evidence

  • That the light flashes two times
  • Whether the blower runs
  • Whether the vent looks intact
  • The model and serial numbers

Try in this order

0 of 9 completed
  1. What to do first

    Reversible

    Note the code and that the heater will not run normally.

  2. Correct only the documented fault domain

    Reversible

    Rheem's bulletin lists a pressure switch fault delay of 2 minutes for a switch that has failed open or closed. Pressure switch work belongs to a technician.

  3. Note the code and the heater's behavior

    Reversible

    Write down two flashes and that the heater will not run normally.

  4. Look at the venting

    Reversible

    Make sure the vent pipe and the termination outside are intact and not blocked by a nest, snow or debris.

  5. Do not bypass the pressure switch

    Reversible

    The switch proves that the blower and the vent are working before the burner lights, so a bypass is dangerous.

  6. Wait out the delay

    Reversible

    Rheem's bulletin lists a fault delay of 2 minutes, so the control waits before it reports and retries.

  7. Call a technician

    Reversible

    Pressure switch work belongs to a technician.

  8. Ask about the vent

    Reversible

    A technician checks the switch, the tube, the blower and the venting together.

  9. Check the vent termination from the ground

    Reversible

    Look at the vent outlet outside, if you can see it safely, for a nest, debris, ice or damage, and tell the technician what you saw.

Model-specific

What is true of this model and not of its siblings

The code on this page
Code 44, two flashes: pressure switch failed closed.
Parts involved
The pressure switch, its tube, the blower and the vent.
Rheem's guidance
The fault delay is 2 minutes, and the work belongs to a technician.
What a failed-closed switch means
The pressure switch is meant to close only when the blower is moving air. If it is closed when the blower is off, it is stuck, and the control refuses to start because it can no longer trust the switch to prove airflow.
Venting and the switch
A blocked vent, a bird's nest in the termination or a crushed pipe can upset the pressure the switch sees. A technician checks the venting as part of the repair, since replacing the switch without clearing the vent only brings the fault back.

Stop boundary

When this stops being a self-service repair

  • !Rheem's bulletin lists a pressure switch fault delay of 2 minutes for a switch that has failed open or closed, and pressure switch work belongs to a technician
  • !Do not bypass the switch
  • !If you smell gas, leave the house and call the gas company

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does display 44 and two flashes mean on a Rheem PowerVent water heater?+

Pressure switch failed closed.

What does the pressure switch do?+

It confirms that the blower is moving air through the vent before the burner is allowed to light.

Can I replace the switch?+

No, it is gas appliance safety equipment.

What is the 2-minute delay?+

The fault delay Rheem lists for a switch that failed open or closed.

Is it urgent?+

The heater will not run properly, so arrange service promptly.

Could a blocked vent cause the code?+

A blocked vent usually causes a failed-open fault, but a technician checks both, since the vent affects the switch.

Is the switch a common failure?+

It is a known wear item on many water heaters, and replacing it is a short job for a technician.