Trane XR95 direct vent condensing gas furnace · exact showing

Trane XR95 direct vent condensing gas furnace showing 5 flashes: meaning and exact next steps

5 flashes means Flame sensed when no flame should be present. This answer applies only to Trane XR95 direct vent condensing gas furnaces whose integrated furnace control flashes an LED, as listed in Table 21 of Trane's installer's guide 18-CD29D1-14-EN. The guide covers the *UH1B, *UH1C and *UH1D models, which Trane's XR 95 data sheet lists by the same numbers. Other Trane furnace families use other controls and other pages.

On the covered Trane XR95 direct vent condensing gas furnace, 5 flashes means flame sensed when no flame should be present. First, note whether the burners are lit or glowing when the furnace is not calling for heat. Then: Flame with no call for heat is a stop condition and points to the gas valve, which is technician work.

Differential

Likely causes of “Trane XR95 direct vent condensing gas furnace showing 5 flashes”, and how to tell them apart

  1. 1

    The furnace senses flame when none should be present (five flashes)

    What separates it The LED flashes five times and the furnace shuts down

    How to confirm Note whether the burners are lit or glowing when the furnace is idle

  2. 2

    A gas valve that leaks through

    What separates it The burners light with no call for heat

    How to confirm Shut off gas and call a technician

  3. 3

    A dirty or failing flame sensor

    What separates it The control thinks it sees a flame

    How to confirm A technician cleans or replaces it

  4. 4

    A short in the flame sensing circuit

    What separates it The sensor wire is damaged

    How to confirm A technician checks the wiring

  5. 5

    A control board fault

    What separates it Everything else is fine

    How to confirm The board is replaced

Before you touch a setting

Record this first — changing settings destroys the evidence

  • That the LED flashes five times
  • Whether the burners are lit when idle
  • Whether you smell gas
  • The furnace model

Try in this order

0 of 8 completed
  1. What to do first

    Reversible

    Note whether the burners are lit or glowing when the furnace is not calling for heat.

  2. Correct only the documented fault domain

    Reversible

    Flame with no call for heat is a stop condition and points to the gas valve, which is technician work.

  3. Look at the burners

    Reversible

    With the furnace idle, look through the viewing window, if there is one, to see whether the burners are lit or glowing when the thermostat is not calling for heat.

  4. Turn the thermostat down

    Reversible

    Set the thermostat well below room temperature so that no call for heat is present.

  5. Shut off the gas

    Reversible

    If the burners stay lit, close the gas valve at the furnace and leave it off.

  6. Check for the smell of gas

    Reversible

    If you smell gas at any time, leave the house and call the gas company from outside.

  7. Call a heating technician

    Reversible

    Trane lists flame sensed with no call for heat as a stop condition, and the usual cause is the gas valve, which is technician work.

  8. Do not restart the furnace

    Reversible

    Leave the furnace off until the valve and the flame sensing circuit have been checked.

Model-specific

What is true of this model and not of its siblings

The code on this page
Five flashes, flame sensed with no call for heat.
Parts involved
The gas valve and the flame sensor.
Source
Trane's service manual for the XR95.
Why this is a stop condition
A furnace should have flame only when it is asked to heat. Flame with no call for heat means the gas valve is not closing or the control is misreading a flame, and either way the furnace should be switched off until a technician has checked it.
A flame sensor can mislead
A dirty or damaged flame sensor can give a false reading, which is a cheaper fault than a leaking valve. A technician can tell the two apart by looking at the burners and testing the sensor, so do not assume the worst, but do not take chances either.

Stop boundary

When this stops being a self-service repair

  • !Flame with no call for heat is a stop condition and points to the gas valve, which is technician work
  • !If you smell gas, leave the house and call the gas company
  • !Do not run the furnace

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does 5 flashes mean on a Trane XR95 direct vent condensing gas furnace?+

Flame sensed when no flame should be present.

Which part is at fault?+

Often the gas valve.

Can I fix it?+

No.

Is five flashes always a leaking gas valve?+

No; a faulty flame sensor can also cause it, but a technician must check, and the furnace should stay off until then.

Can I clean the flame sensor myself?+

Some owners do, but when the code is flame with no call for heat, leave it to a technician.

Wrong device or version?

Match the path before repeating the steps.

Match another device