On the covered York TM9V two-stage variable-speed gas furnace, 2 red flashes means the pressure switch is closed when it should be open. The control confirms the switch contacts are open at the beginning of each heat cycle and will not let the ignition sequence continue if they are closed. First, note that the code appears at the start of a heating call.
Differential
Likely causes of “York TM9V two-stage variable-speed gas furnace showing 2 red flashes”, and how to tell them apart
- 1
A pressure switch stuck closed
What separates it The code appears at the start of a heating call
How to confirm Technician testing
- 2
A pressure transducer fault
What separates it Readings are wrong at rest
How to confirm Technician testing
- 3
A shorted wire to the switch
What separates it Switch always closed
How to confirm Technician inspection
- 4
A tube with water in it
What separates it The switch reads wrongly
How to confirm Technician draining
- 5
A control fault
What separates it Parts test well
How to confirm Technician diagnosis
Before you touch a setting
Record this first — changing settings destroys the evidence
- That the LED shows two red flashes
- That it appears at the start of the call
- Recent service
- Whether the inducer starts
Try in this order
0 of 8 completedWhat to do first
ReversibleNote that the code appears at the start of a heating call.
Correct only the documented fault domain
ReversibleYork's manual says to check for a faulty pressure switch or miswiring. That is technician work.
Turn the thermostat off
ReversibleThen call for heat again.
Note when the code appears
ReversibleStart of the call?
Listen for the inducer
ReversibleDoes it start?
Do not tamper with the switch
ReversibleIt is a safety part.
Record the date
ReversibleAnd the weather.
Call a technician
ReversibleFor the switch and transducer.
Model-specific
What is true of this model and not of its siblings
- Open before start
- Before every cycle the control checks that the pressure switch is open, which shows it is not stuck. A closed switch at rest is a fault.
- York's guidance
- York says to check the pressure switch and the pressure transducer, both of which are sensing and safety parts.
- A stuck switch
- Dirt, corrosion or condensate can hold the contacts together.
- A wiring cause
- A pinched wire may short the circuit.
- Why a technician
- Replacing a safety switch with a wrong part is a danger.
- Heat in the meantime
- Use safe alternatives and keep the house warm enough to protect pipes.
- A check you never see
- Every time the thermostat calls for heat, before the inducer starts, the control looks at the pressure switch and expects it to be open. The check happens in a fraction of a second. If the switch is closed, the control refuses to proceed, and you see two flashes.
- Hose and tube clues
- The switch is connected to the furnace by a small rubber tube. A tube that has collapsed, filled with water or bent can hold the switch in the wrong state. A technician checks the tube, the tap on the vent and the switch itself.
- Why safety parts are not swapped by guess
- A pressure switch is rated for a specific pressure. A part with the wrong rating may close at the wrong time and allow the furnace to run with a blocked vent. Ask that the replacement match York's part number for your model.
Stop boundary
When this stops being a self-service repair
- !Never bypass, jumper or tape over a safety switch
- !Stop for a carbon monoxide alarm, soot, scorch marks or flame outside the burner compartment
- !Call a qualified technician for anything behind the furnace's panels
- !If you smell gas, leave the building and call the gas utility from outside; do not use switches or phones inside
Evidence ledger
Sources behind this answer
Exact questions
Common questions
What does 2 red flashes mean on a York TM9V two-stage variable-speed gas furnace?+
The pressure switch is closed when it should be open. The control confirms the switch contacts are open at the beginning of each heat cycle and will not let the ignition sequence continue if they are closed.
What do two red flashes mean on a York TM9V?+
The pressure switch is closed when it should be open.
Why does that matter?+
The control must see the switch open before the inducer starts.
What tests it?+
A technician's meter.
Can I replace it?+
No, call a technician.