On the covered York TM9V two-stage variable-speed gas furnace, a steady-on LED in any color means Control failure. First, turn power to the furnace off and back on, and note whether the LED comes back steady. Then: york's manual says that if the fault code returns after cycling the power, the control board must be replaced, and that the control board is not field-repairable.
Differential
Likely causes of “York TM9V two-stage variable-speed gas furnace showing a steady-on LED in any color”, and how to tell them apart
- 1
A control board failure
What separates it The LED stays on, in any color, and nothing runs
How to confirm York names the steady LED as a control failure
- 2
A power glitch
What separates it The LED clears after a power cycle
How to confirm Cycle the power once
- 3
A loose connector
What separates it The furnace was recently serviced
How to confirm Technician inspection
- 4
A surge or storm damage
What separates it The code follows lightning or an outage
How to confirm Technician inspection
- 5
A failing power supply to the board
What separates it The LED flickers
How to confirm Technician testing
Before you touch a setting
Record this first — changing settings destroys the evidence
- That the LED is steady, not flashing
- The LED's color
- Whether it follows a storm or an outage
- Whether cycling the power changes it
Try in this order
0 of 8 completedWhat to do first
ReversibleTurn power to the furnace off and back on, and note whether the LED comes back steady.
Correct only the documented fault domain
ReversibleYork's manual says that if the fault code returns after cycling the power, the control board must be replaced, and that the control board is not field-repairable.
Turn the furnace off
ReversibleAt the switch.
Wait one minute
ReversibleThen turn it on.
Look at the LED
ReversibleSteady or flashing?
If steady again
ReversibleDo not repeat more than once.
Note the date
ReversibleAnd any storm.
Call a technician
ReversibleThe board needs replacing.
Model-specific
What is true of this model and not of its siblings
- A different kind of signal
- Most York codes are counted flashes. A steady light that does not flash is a different signal: the control itself has detected an internal fault and cannot run its program.
- York's statement
- York says that if the code returns after a power cycle, the control board must be replaced, and that the board is not field repairable.
- Surge protection
- A whole-house surge protector or a plug-in one for the furnace can reduce board failures, and a technician can fit one.
- What a replacement involves
- The technician swaps the board, moves the connectors and sets the model ID plug. The furnace is tested through a full cycle.
- Warranty
- Boards often have a parts warranty. Have the model and serial numbers ready.
- Temporary heat
- Use safe electric heaters while you wait, and never a gas oven.
- Reading the light correctly
- A control board shows its state with one LED. A steady light, not flashing, is a different message from any counted flash code. If the light is off, the board has no power and the cause may be a switch, a fuse or the transformer. If it is steady, the board has power but has stopped. Note which of these you see.
- Protecting the new board
- Boards are sensitive to surges and static. A surge protector built for HVAC equipment can reduce failures, and technicians will wear a wrist strap when handling a board. Ask them about it if boards have failed before.
- Before you pay for a board
- Ask the technician to confirm the board has failed by testing the 24 volt supply and the connections. A board that fails because of a short in a component will fail again if the short is not found. Ask whether the repair includes testing the parts the board drives.
Stop boundary
When this stops being a self-service repair
- !Never bypass, jumper or tape over a safety switch
- !Stop for a carbon monoxide alarm, soot, scorch marks or flame outside the burner compartment
- !Call a qualified technician for anything behind the furnace's panels
- !If you smell gas, leave the building and call the gas utility from outside; do not use switches or phones inside
Evidence ledger
Sources behind this answer
Exact questions
Common questions
What does a steady-on LED in any color mean on a York TM9V two-stage variable-speed gas furnace?+
Control failure.
What does a steady LED mean on a York TM9V?+
A control failure.
Does the color matter?+
York says any color.
Can the board be repaired?+
York says it is not field repairable.
Will a power cycle fix it?+
If it does not return, it may.