Amana range · exact code

Amana range code F1-9: meaning and exact next steps

F1-9 means the slave microprocessor on the clock board is not working, which points at the electronic oven control This answer applies only to Amana ranges with electronic controls (built on the control platform Whirlpool Corporation shares across its brands). A code can name a different fault on another platform, so match the code to the model.

On the covered Amana range, F1-9 means the slave microprocessor on the clock board is not working, which points at the electronic oven control First, turn the breaker off for one minute and back on. Then: if F1-9 returns within the minute after a reset, replace the control board (the clock).

Differential

Likely causes of “Amana range code F1-9”, and how to tell them apart

  1. 1

    The clock board's second microprocessor has stopped working

    What separates it F1-9 appears and the oven will not bake or the clock is blank

    How to confirm Amana's table calls it Slave Micro Not Functioning and points at the clock control board

  2. 2

    A one-time glitch after a power surge

    What separates it The code shows once, usually after a storm or a breaker trip, and clears

    How to confirm Reset at the breaker and see whether it stays gone for a day

  3. 3

    A failing electronic range control

    What separates it F1-9 returns within a week of a reset

    How to confirm A code that comes back is the control wearing out, not a setting

  4. 4

    An older clock control reaching the end of its life

    What separates it F1-9 on a range that is many years old, with a clock that has already drifted or blanked

    How to confirm Age is the clue: these clock boards use parts that dry out, and a replacement board is the answer when the code recurs

Before you touch a setting

Record this first — changing settings destroys the evidence

  • Whether the display and clock still work
  • How soon F1-9 comes back after a reset
  • Whether a storm or a tripped breaker came first
  • The model number from the frame behind the oven door

Try in this order

0 of 6 completed
  1. What to do first

    Reversible

    turn the breaker off for one minute and back on.

  2. Correct only the documented fault domain

    Reversible

    If F1-9 returns within the minute after a reset, replace the control board (the clock). A power reset is the whole of what Amana publishes for this code: remove power for 1 minute, restore it, and watch whether the code returns.

  3. Turn the breaker off for one minute

    Reversible

    Power the range down at the circuit breaker, wait a full minute, switch it back on and watch the oven for a minute to see whether F1-9 reappears.

  4. Check that the oven works

    Reversible

    Set a short bake. If the oven heats and the code stays away, note the date and watch for a repeat.

  5. Plan the control board

    Reversible

    If F1-9 returns, the clock board, also called the electronic range control, is the part Amana's table names. A repeat inside a week means the part has failed.

  6. Write down the clock behavior before you reset

    Reversible

    Note whether the clock was blank, flashing or wrong before F1-9 appeared. A clock board that has been misbehaving for weeks before the code points at the board itself, while a code that appears once after a storm points at the power.

Model-specific

What is true of this model and not of its siblings

Shown as
F1-9 on an older Amana electronic clock control.
Part named
Electronic range control, also called the clock.

Stop boundary

When this stops being a self-service repair

  • !Do not open the control panel with the power on
  • !Book Amana service if the code returns after one clean reset

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does F1-9 mean on a Amana range?+

the slave microprocessor on the clock board is not working, which points at the electronic oven control

Is F1-9 the same as F1 E9?+

They name the same family of control faults on different generations of controls. F1 E9 is the newer way of showing it.

Can I keep cooking on the stovetop?+

Surface burners on most electric ranges run on their own switches and often keep working, but follow the manual for your model.

My Amana range shows F1-9 and the stovetop still works. Is that normal?+

On many electric ranges the surface burners are switched separately from the oven control, so they can keep working while the clock and oven control fail. Use the burners with care and book the control repair.

Should I buy the part myself?+

The clock control is matched to the model number on the frame behind the oven door. Take that number, not the code, to a parts seller, and have the old board's connectors photographed before you pull anything.

Wrong device or version?

Match the path before repeating the steps.

Match another device