Rheem PowerVent water heater · exact signal

Rheem PowerVent water heater display 93 and eight-four flashes: meaning and exact next steps

display 93 and eight-four flashes means A valve fault was detected. This answer applies only to Rheem PowerVent ESII gas water heaters with the Honeywell electronic control, per Rheem Technical Service Bulletin 1627. The gas valve status light flashes a count with a three-second pause, and the electronic control also shows a two-digit display code. Other Rheem water heaters use other controls.

On the covered Rheem PowerVent water heater, display 93 and eight-four flashes means a valve fault was detected. First, turn the gas control to off. Then: Rheem's bulletin lists this as a gas valve fault. Gas valve work belongs to a technician.

Differential

Likely causes of “Rheem PowerVent water heater display 93 and eight-four flashes”, and how to tell them apart

  1. 1

    A gas valve fault was detected

    What separates it The status light flashes eight times and then four times

    How to confirm Turn the gas control to off

  2. 2

    A gas valve that has failed

    What separates it The valve does not respond

    How to confirm A technician replaces it

  3. 3

    A wiring fault to the valve

    What separates it The harness is damaged

    How to confirm A technician checks the wiring

  4. 4

    A control that cannot drive the valve

    What separates it The control board has failed

    How to confirm A technician tests the control

  5. 5

    A one-off fault after a power event

    What separates it The code appeared once

    How to confirm A technician resets and tests

Before you touch a setting

Record this first — changing settings destroys the evidence

  • That the pattern is eight flashes, a pause and four flashes
  • Whether the heater lights at all or refuses to start
  • Whether you smell gas around the heater
  • The model and serial numbers from the label on the tank

Try in this order

0 of 10 completed
  1. What to do first

    Reversible

    Turn the gas control to off.

  2. Correct only the documented fault domain

    Reversible

    Rheem's bulletin lists this as a gas valve fault. Gas valve work belongs to a technician.

  3. Turn the gas control to off

    Reversible

    This is the first step, so that no gas can flow.

  4. Check for gas

    Reversible

    If you smell gas, leave the house and call the gas company.

  5. Note the pattern and the model

    Reversible

    Write down the eight then four flashes and the model number.

  6. Do not open the valve

    Reversible

    Gas valve work belongs to a technician.

  7. Call a technician

    Reversible

    Ask for a gas valve and control check.

  8. Keep the heater off

    Reversible

    Until it has been checked.

  9. Arrange hot water in the meantime

    Reversible

    While the heater is off, plan for showers and washing elsewhere, or heat water on the stove for essentials, until the technician has repaired the valve.

  10. Count the second group of flashes

    Reversible

    Watch the light for two full cycles and count each group. Writing the pair down avoids mixing up eight-four with eight-two.

Model-specific

What is true of this model and not of its siblings

The code on this page
Code 93, eight then four flashes: valve fault.
Parts involved
The gas valve, its wiring and the control.
Rheem's guidance
Gas valve work belongs to a technician.
What the gas valve does
The gas valve is the electrically controlled door that lets gas to the burner. The control opens it only when every safety check passes, and a valve fault means the control cannot confirm that the valve is doing what it is told, which is why the heater stops.
Why only a technician
Gas valves are part of the appliance's safety system and are certified as a unit. Repairing or replacing one needs the right part number, the right tools to check for leaks and a license in most places, so the repair belongs to a qualified technician.
Two pairs of flashes
Rheem's PowerVent heater with the Honeywell control reports many faults with two counts, eight flashes and then a second group. The second group tells you which eight-series fault it is. Eight and four is the valve fault, and eight and two is the temperature sensor, so count carefully and write the pair down for the technician.
Valve and wiring
The valve is operated by a small electrical coil, and a loose or corroded connector at the coil can look like a failed valve. A technician checks the connector and the coil's resistance before replacing the valve, which can save a good part of the repair cost.

Stop boundary

When this stops being a self-service repair

  • !Ask the technician to test the valve's coil and its wiring before replacing the whole valve, as the control may not be seeing the valve properly
  • !Keep the gas control at OFF until the valve has been tested
  • !If you smell gas, leave and call the gas company

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does display 93 and eight-four flashes mean on a Rheem PowerVent water heater?+

A valve fault was detected.

Can I fix it?+

No, gas valve work belongs to a technician.

Will resetting help?+

Do not reset repeatedly.

Is the valve costly?+

It is a moderate to dear part.

Can the heater be used while it waits for the repair?+

No, keep it off, since the valve is part of the safety system.

Can I have hot water meanwhile?+

Heating water on another appliance, or a short stay with friends, is safer than running the heater with a valve fault.

How long does the repair take?+

Often a single visit, if the technician has the valve, but ask when you book.

How do I tell eight-four from eight-two?+

Count the second group of flashes after the pause: four means the valve, and two means the temperature sensor.

Can a loose connector cause a valve fault?+

Yes, a corroded or loose connector at the valve can mimic a failed valve.