Rheem tankless gas water heater · exact code

Rheem tankless gas water heater code 05: meaning and exact next steps

05 means Warning: the flame rod has detected improper burner combustion, on indoor units only. Rheem's pocket manual says it is commonly caused by venting and/or gas supply. This answer applies only to Rheem tankless gas water heaters whose remote control or display shows a two-character code, as listed in Rheem's RTG Use and Care manual and its tankless troubleshooting pocket manual (SVC820 (P)). The manuals separate indoor from outdoor units and mid-efficiency from high-efficiency (condensing) units, and a row says where a code applies to one type.

On the covered Rheem tankless gas water heater, 05 means warning: the flame rod has detected improper burner combustion, on indoor units only. Rheem's pocket manual says it is commonly caused by venting and/or gas supply. First, check that the vent and air intake are clear and connected.

Differential

Likely causes of “Rheem tankless gas water heater code 05”, and how to tell them apart

  1. 1

    A restricted vent or air intake

    What separates it The flame rod detects improper burning

    How to confirm Check that the vent and intake are clear and connected

  2. 2

    A gas supply problem

    What separates it The flame is unstable

    How to confirm Have the supply checked

  3. 3

    A warning before a fault

    What separates it Code 05 is a warning

    How to confirm Fix the cause before it becomes code 13

  4. 4

    A dirty burner or rod

    What separates it Slightly poor combustion

    How to confirm Technician cleaning

  5. 5

    A wrong altitude setting

    What separates it Combustion is off

    How to confirm Technician checks the setting

Before you touch a setting

Record this first — changing settings destroys the evidence

  • Whether the unit still heats
  • The vent state
  • Whether the code becomes 13

Try in this order

0 of 6 completed
  1. What to do first

    Reversible

    Check that the vent and air intake are clear and connected.

  2. Correct only the documented fault domain

    Reversible

    Rheem's pocket manual points to venting and gas supply as the usual cause. Rheem's steps when a code shows: turn on a hot water faucet and recheck the remote control display. If the code stays, turn off the faucet and the water heater, unplug the water heater for about 30 seconds and plug it back in, follow the chart for your code, restart the water heater and recheck. If the code is still shown, turn off the faucet and the water heater, note the code and call for service. If a code is not in the chart, turn the water heater off immediately and call for service.

  3. Check the vent and intake

    Reversible

    Clear and connected.

  4. Check the gas supply

    Reversible

    With the supplier if unsure.

  5. Watch for code 13

    Reversible

    It may follow.

  6. Do not ignore it

    Reversible

    It warns of a fault.

Model-specific

What is true of this model and not of its siblings

A warning, not a stop
Code 05 is the early warning. The unit keeps running while it reports poor combustion; if the condition worsens, it becomes an error such as code 13 and the unit stops.
Indoor only
The code applies to indoor units, whose venting and air supply are more likely to be restricted.
Act early
Clearing a vent or having the gas supply checked at the warning stage avoids a shutdown.
A warning stage
Rheem separates a warning, code 05, from the error that follows if the condition worsens. The unit keeps heating while it reports that the flame rod sees improper burning. That is your chance to act before it stops.
Where to look
Rheem names the vent and the gas supply. From outside, look at the vent and air intake terminals for blockage. Inside, check that nothing stands against the unit. If a gas appliance elsewhere also burns poorly, suspect the gas supply.
When it becomes code 13
If the warning is ignored and combustion worsens, the heater stops and shows code 13. The cure is the same, and a technician should look at it before then.
Questions for the installer
Ask whether the vent run is within the length and bend limits in the manual, whether the gas line is sized for the total load and whether DIP switch 2 matches your elevation. A short visit to check these three things often stops the warning for good.
Keeping a log
Note the date and the weather when the warning appears. Wind can push exhaust back into a vent, and a heater that warns only on windy days points at the vent terminal, which a technician can fit with a wind guard.
A seasonal pattern
Venting problems often follow the seasons. In autumn, leaves and spider nests find their way into terminals, in winter, snow and ice can cap an intake, and in spring, birds nest in warm vent terminals. If the warning comes and goes with the weather, the vent terminal is the first place to look, and a guard fitted by the installer prevents most of it.
Gas appliances together
If you have a gas range or dryer on the same line, run them while the heater runs to see whether the flame at the stove changes. A weak stove flame while the heater fires points to a gas line that is too small for the combined load, which only the gas supplier or installer can correct.

Stop boundary

When this stops being a self-service repair

  • !Rheem points to venting and gas supply as the usual cause
  • !Do not ignore a warning

Evidence ledger

Sources behind this answer

Exact questions

Common questions

What does 05 mean on a Rheem tankless gas water heater?+

Warning: the flame rod has detected improper burner combustion, on indoor units only. Rheem's pocket manual says it is commonly caused by venting and/or gas supply.

What does code 05 mean on a Rheem tankless?+

A warning that the flame rod detected improper combustion.

Does it apply to outdoor units?+

It applies to indoor units only.

Wrong device or version?

Match the path before repeating the steps.

Match another device