On the covered Rheem tankless gas water heater, 05 means warning: the flame rod has detected improper burner combustion, on indoor units only. Rheem's pocket manual says it is commonly caused by venting and/or gas supply. First, check that the vent and air intake are clear and connected.
Differential
Likely causes of “Rheem tankless gas water heater code 05”, and how to tell them apart
- 1
A restricted vent or air intake
What separates it The flame rod detects improper burning
How to confirm Check that the vent and intake are clear and connected
- 2
A gas supply problem
What separates it The flame is unstable
How to confirm Have the supply checked
- 3
A warning before a fault
What separates it Code 05 is a warning
How to confirm Fix the cause before it becomes code 13
- 4
A dirty burner or rod
What separates it Slightly poor combustion
How to confirm Technician cleaning
- 5
A wrong altitude setting
What separates it Combustion is off
How to confirm Technician checks the setting
Before you touch a setting
Record this first — changing settings destroys the evidence
- Whether the unit still heats
- The vent state
- Whether the code becomes 13
Try in this order
0 of 6 completedWhat to do first
ReversibleCheck that the vent and air intake are clear and connected.
Correct only the documented fault domain
ReversibleRheem's pocket manual points to venting and gas supply as the usual cause. Rheem's steps when a code shows: turn on a hot water faucet and recheck the remote control display. If the code stays, turn off the faucet and the water heater, unplug the water heater for about 30 seconds and plug it back in, follow the chart for your code, restart the water heater and recheck. If the code is still shown, turn off the faucet and the water heater, note the code and call for service. If a code is not in the chart, turn the water heater off immediately and call for service.
Check the vent and intake
ReversibleClear and connected.
Check the gas supply
ReversibleWith the supplier if unsure.
Watch for code 13
ReversibleIt may follow.
Do not ignore it
ReversibleIt warns of a fault.
Model-specific
What is true of this model and not of its siblings
- A warning, not a stop
- Code 05 is the early warning. The unit keeps running while it reports poor combustion; if the condition worsens, it becomes an error such as code 13 and the unit stops.
- Indoor only
- The code applies to indoor units, whose venting and air supply are more likely to be restricted.
- Act early
- Clearing a vent or having the gas supply checked at the warning stage avoids a shutdown.
- A warning stage
- Rheem separates a warning, code 05, from the error that follows if the condition worsens. The unit keeps heating while it reports that the flame rod sees improper burning. That is your chance to act before it stops.
- Where to look
- Rheem names the vent and the gas supply. From outside, look at the vent and air intake terminals for blockage. Inside, check that nothing stands against the unit. If a gas appliance elsewhere also burns poorly, suspect the gas supply.
- When it becomes code 13
- If the warning is ignored and combustion worsens, the heater stops and shows code 13. The cure is the same, and a technician should look at it before then.
- Questions for the installer
- Ask whether the vent run is within the length and bend limits in the manual, whether the gas line is sized for the total load and whether DIP switch 2 matches your elevation. A short visit to check these three things often stops the warning for good.
- Keeping a log
- Note the date and the weather when the warning appears. Wind can push exhaust back into a vent, and a heater that warns only on windy days points at the vent terminal, which a technician can fit with a wind guard.
- A seasonal pattern
- Venting problems often follow the seasons. In autumn, leaves and spider nests find their way into terminals, in winter, snow and ice can cap an intake, and in spring, birds nest in warm vent terminals. If the warning comes and goes with the weather, the vent terminal is the first place to look, and a guard fitted by the installer prevents most of it.
- Gas appliances together
- If you have a gas range or dryer on the same line, run them while the heater runs to see whether the flame at the stove changes. A weak stove flame while the heater fires points to a gas line that is too small for the combined load, which only the gas supplier or installer can correct.
Stop boundary
When this stops being a self-service repair
- !Rheem points to venting and gas supply as the usual cause
- !Do not ignore a warning
Evidence ledger
Sources behind this answer
Exact questions
Common questions
What does 05 mean on a Rheem tankless gas water heater?+
Warning: the flame rod has detected improper burner combustion, on indoor units only. Rheem's pocket manual says it is commonly caused by venting and/or gas supply.
What does code 05 mean on a Rheem tankless?+
A warning that the flame rod detected improper combustion.
Does it apply to outdoor units?+
It applies to indoor units only.