Westinghouse iGen4500 generator error codes
Westinghouse iGen4500 generator indicators as Westinghouse Outdoor Power Equipment lists them, each with its meaning and the first safe check.
- low-oil-led-on-engine-stoppedLow engine oil. Westinghouse says that when the
- no-lights-or-no-response-to-start-buttonThe generator will not start. Westinghouse's first listed
- overload-led-on-output-ready-offThe generator is overloaded, or there is a
Every code
Every Westinghouse iGen4500 generator code: what it means and what to do
- low-oil-led-on-engine-stopped
- no-lights-or-no-response-to-start-button
- overload-led-on-output-ready-off
Westinghouse iGen4500 generator code low-oil-led-on-engine-stopped
Low engine oil. Westinghouse says that when the oil level in the crankcase falls below the safe operating limit, the Low Oil LED lights and the generator automatically shuts off the engine.
Turn the battery switch to the OFF position, then check the engine oil level on a level surface.
Westinghouse's troubleshooting table for a generator stopped by low oil: with the Low Oil LED lit, turn the battery switch to OFF and add engine oil. If the oil level is right and the engine still starts and then shuts down, the table lists a defective low oil level switch and says to contact Westinghouse customer service.
Westinghouse iGen4500 generator code overload-led-on-output-ready-off
The generator is overloaded, or there is a short circuit in a connected appliance. Westinghouse says the generator switches off all AC output to protect itself while the engine keeps running, the OVERLOAD light shows red and the green OUTPUT READY light goes off.
Turn off and unplug everything connected to the generator.
Westinghouse's steps to restore AC output: with all loads off and unplugged, push the RESET button on the control panel until the OVERLOAD LED goes off and OUTPUT READY lights; reset any circuit breakers that are off; verify the running and surge loads do not exceed the generator's capacity; and reconnect loads one at a time, letting the generator stabilize after each. Westinghouse warns that marginal overloading that briefly lights the OVERLOAD LED may shorten the generator's service life. Its no-power table also lists checking the AC load and the air inlet, and stopping and restarting the engine.
Westinghouse Outdoor Power Equipment — User Manual: iGen4500 Digital Inverter Generator